The Automatic Cleveland Open Cup Flash Point Apparatus are suitable for the determination of petroleum products according to the standard petroleum products flash point and ignition point determination method (Cleveland open cup method) except for fuel oil and petroleum products with open flash point lower than 79℃.

The instrument is designed as a table-top structure, with stainless steel working table and stainless steel heating furnace shell, which is beautiful and elegant. The Automatic Cleveland Open Cup Flash Point Apparatus are equipped with flame extinguishing cover, which meets the requirements of the ignition point test.

Features

We believe that our Automatic Cleveland Open Cup Flash Point Apparatus can compete with any other similar products in terms of quality performance as well as price. It adopts a special heating furnace form to ensure the safety of the test. And its heating power is continuously adjustable to meet the requirements of the test. In addition, the instrument is complete, the user only needs to match the gas or other civil gas can be tested, it is very simple and convenient to use.

HZKS-3 Automatic COC Cleveland Open Cup Flash Point Apparatus

Technical Parameters

Temperature Measurement

Temperature measuring range

-59.9°C~399.9°C

Temperature Control Range

Room temperature~400°C

Repeatability

≤150℃ 3℃, >150℃ 5℃

Resolution

0.1°C

Precision

0.5%

Temperature Sensor

Platinum Resistor(PT100)

Flash Fire Sensor

Ion detection ring

Ambient Temperature

0 ~ 40°C

Relative Humidity

≤ 85% RH

Power Supply

AC220V ± 20%; 50HZ ± 10%

Power Consumption

Approx 400W

Overall Dimension

440X280X290(mm)

Instrument Weight

14kg

Failure And Treatment

NO.

Failure

Treatment

1

Turn on the power, the LCD screen no display

Check power supply is plugged in, open the instrument measured the board examines the plug is not loose.

2

Large repeatability error for sample testing

Remove the lifting arm top cover, and check
1. whether the mixer shaft is broken
2. Oil may affect thermocouple sensitivity, plz dry it with filter paper

3

No heating

Electric wire broken

4

Lift arm rise or fall failure

Limit opt coupler damage
The screw between the main engine and lift arm fell off